DF53/DF98 Power Supply Impedance for Fieldbus

These modules were specially designed to provide appropriate impedance for fieldbus networks.

Description

The purpose of this impedance is to implement an output circuit where the impedance is greater than 3 KΩ, and when assembling in parallel with two 100 Ω ±2% terminators, it results in 50 Ω line impedance approximately. This impedance can be implemented in a passive mode (50 Ω resistance in series with a 100 mH inductance) or in an active mode, through an impedance control circuit.

The fieldbus power supply impedance is a non-isolated, active impedance control device, in compliance with IEC 61158-2 standard. This device provides output impedance which, in parallel with the two bus terminators (a 100 Ω resistor in series with a 1 mF capacitor) required by the standard, results in a pure resistive line impedance for a broad frequency range. DF53 and DF98 were designed to work in non-hazardous areas.