Showing 17–32 of 97 results

AM01P Auto/Manual Transfer Station

The Auto/Manual Transfer Station AM01P is an auxiliary device that allows the switching from automatic to manual and from manual to automatic without bumping the process. The manual output signal can be adjusted by the frontal knob. The output signal is indicated by the built-in indicator. The power supply is isolated from the inputs and outputs.

AT303 Profibus-DP Active Terminator

The AT303 is an active terminator developed to increase the PROFIBUS-DP network availability and facilitate accessing any node on the PROFIBUS-DP bus without putting the network in an intermittent condition. This way, any network slave can be switched off, removed or replaced without harming the communication, especially when the terminators are enabled on the network end slaves.

The AT303 terminator can be mounted inside the panels with DIN rail or even on the field in boxes.

AuditFlow Flow Measurement System

According to current international standards for custody transfer flow measurement systems, AuditFlow provides a comprehensive solution in a Flow Measurement System. In addition to calculating flow corrections in real time, it has data security, audit trail, diagnosis and procedure in case of failure accordint to such standards.

Application :  

AuditTank Tank Measurement System

The TM302 and TMView Measurement System was designed for International Standards focusing applications like inventory control, custody transfer, well test using tank and leak detection. Based on AuditFlow – Flow Measurement System where the application is the fiscal measurement and custody transfer, Smar innovates by incorporating the audit trail characteristic to the Tank Measurement System. Due to its hardware modular configuration, as well the FOUNDATION™ fieldbus, MODBUS RTU and TCP/IP protocols as a built-in feature in the TM302 module, many options of architecture and connectivity are available to the user.

BFY-CL Coupling Device

BFY-CL is a coupling device for the FY family of SMAR positioners, designed for applications in several different models of final control elements.

BFY-CL attends to the needs of modulating controls for processes requiring strokes longer than 100 mm in the final control element.

The operation principle of BFY-CL is based on the oblique split rule, reducing a original long stroke to a short one, orthogonal to the original travel.

The BFY applications are many. From the modulation in control cylinders of long stroke to acting as floodgates of high capacity.

The BFY-CL is used with the FY301 / FY302 / FY303 / FY400 SMAR positioners – presented in HART®/4-20 mA, Foundation fieldbus™ andProfibus PA communication protocol versions.

BT302 Foundation Fieldbus & Profibus-PA Bus Terminator

BT302 is a fieldbus bus terminator for PROFIBUS-PA and FOUNDATION fieldbus in compliance
with FISCO model and Entity model.

The function of the bus terminator is to prevent signal reflection and noise in the fieldbus network. Due to its small size and particular shape the BT302 can easily be mounted directly in any junction box only using two screws.

The BT302 has industrial grade packing, the internals of it are hermetically sealed, eliminating impact from humidity and other environmental factors. This device complies with the requirements of IEC 61158-2 (ISA –S50.02-1992) and it may be used both in safe and hazardous areas, in accordance with the intrinsic safety standards requirements.

CIV200P Current to Voltage Converter

  • The CIV200P is a Current / Voltage Converter, nonisolated.
  • It converts a 4-20 mA current into a voltage output, which range is determined by an internal jumper
    selection.
  • An adjustable resistor can be used as input, in manual mode, to generate the voltage output.

CONF600 Plus CD600Plus Configuration Tools

CONF600 Plus is the CD600 configuration interface, developed for Windows, that offers graphic resources and easy Human-Machine Interface operation.

With the CONF600 Plus, it is possible to create, edit, optimize and download the CD600 Plus control strategies and it is also possible to calibrate inputs and outputs, monitor online function blocks, to configure block parameters, to take notes and print the whole documentation.

CONF700 LC700 Configuration Tool

The CONF700 is a Windows based software designed for configuring the LC700 Universal Hybrid Programmable Controller. It has a powerful user interface which is easy to use and learn.

CONF700 uses ‘Ladder Logic’, an easy configuration language. Its elements are Coils, Relays and Function Blocks to build a Configuration. The user will be able to define the hardware for the LC700 controller, design the control logic using Ladder Logic based on IEC-61131-3, define User Functions, test and also optimize the configuration. CONF700 also includes tools for monitoring and editing variables and parameters online.

The control strategy is achieved with Logical Networks in a Ladder style that supports hybridization with a rich library of built-in Function Blocks. The number of Logic Networks is only limited by the memory size. An included Network Manager supports enabling, disabling and changing of the execution order of Networks.

CRG300 Cable Route Guide

This is a mechanical device that facilitates the routing of PROFIBUS-PA, PROFIBUS-DP, FOUNDATION fieldbus, AS-i, DeviceNet, Modbus and Conventional cables to guarantee the correct bending of the cable, respecting the minimum bending. Whenever this bending is violated there is a change in the cable impedance, causing signal reflection. This device was designed for cabinet and field mounting.

DC302 Foundation Fieldbus Remote I/O

The DC302 Fieldbus Remote I/O makes the integration of Fieldbus and conventional I/O easy. It is a single integrated easy to use piece of equipment including power, control, networking and I/O under one compact device requiring less panel space than other solutions. The DC302 is an integral part of SYSTEM302 but also integrates into other systems supporting Foundation Fieldbus.

DC303 Profibus-PA Remote I/O

The DC303 Profibus-PA Remote I/O makes the integration of Profibus and conventional I/O easy. It is a single integrated easy to use piece of equipment including power, control, networking and I/O under one compact device requiring less panel space than other solutions. The DC303 is an integral part of SYSTEM302 but also integrates into other systems supporting Profibus.

DF100 HSE/WirelessHART™ Controller

The DF100 controller is a key element in the distributed architecture of the field control systems. Combines powerful communication features with access to field devices via WirelessHART™ protocol.

This controller has features entirely new when compared with the DFI302 modular line. The DF100 can be used in outdoors, because it has ingress protection IP66. In addition, it makes possible to work with the new specification HSE WIO of Fieldbus Foundation, and Modbus communication via RS-485 port.

DF50 Power Supply for Backplane

Module provides two voltage outputs:

  • 5Vdc @ 3 A: distributed by Power Lines in the Inter-Module-Bus (IMB) throughout the racks to feed module circuits;
  • 24 Vdc @ 300 mA: for external use through the terminals 1B and 2B.

 

DF52/60 H1 Foundation Fieldbus & Profibus-PA Power Supply

The DF52 power supply unit is a non-intrinsically safe equipment with an universal AC input (90 to 264 Vac, 47 to 63 Hz or 127 to 135 Vdc), and a 24 Vdc output, isolated, with short-circuit and over-current protection, ripple and fault indication, appropriated to power fieldbus elements.

The DF60 power supply unit is a non-intrinsically safe equipment with a DC input (20 to 30 Vdc) and a 24 Vdc output, isolated, with short-circuit and over-current protection, ripple and fault indication, appropriated to power fieldbus elements.