Showing 17–32 of 62 results
The moving-iron panel voltmeter with a change-over switch is adapted for measuring line-to-line and phase-to-phase RMS voltages in 3-phase 4-wire power networks. A six-positional switch installed on the meter frontal side enables the choice of the measured voltage in six different points of the network system.
The N20 meter is a digital programmable panel instrument destined for measurements of d.c. voltages or d.c. currents: unipolar or bipolar, temperature through thermocouples (J, K) and Pt100 resistance
thermometers. The readout field is a LED display which enables the exposition of results in red, green or orange colours. The LPCon program is destined for the configuration of the N20 meter. The N20 meter must be connected to the PC computer through a PD14 programmer.
Following parameters can be reprogrammed:
– display colour, individually in three intervals,
– thresholds of displayed overflows
– display precision of the result (decimal point),
– highlight of the unit,
– automatic or manual compensation: temperature of ends in measurements with thermocouples, or wire resistance in Pt100 measurements,
– averaging time of the measurement,
– recalculation of indications (individual characteristic),
– two alarms of OC type operating in six working modes.
The alarm output switching on is signaled by the highlight of the triangular alarm index situated at the left display side, for the suitable alarm digit. The highlight colour is always different from the colour of the displayed (measured) value. The meter has a galvanic separation between the supply, measuring inputs and the programmer input. The protection level from the frontal side is IP65. Meter overall dimensions: 96 ´ 48 ´ 64 mm (including terminals).
The N20Z meter is a digital programmable panel instrument destined for measurements of a.c. voltages, a.c. currents, or frequency. The readout display is a LED display which enables the exposition of results in red, green or orange colour. The LPCon program is destined for the configuration of the N20Z meter. The meter must be connected with the PC computer through a PD14 converter.
Parameters which can be reprogrammed are as follows:
– display colour, individually in three intervals,
– thresholds of displayed overflows,
– display precision of the result (decimal point),
– highlight of the unit,
– kind of the measured signal a.c. or a.c. + d.c. (True RMS),
– averaging time of the measurement,
– recounting of indications (individual characteristic),
– two alarms of OC type operating in six working modes.
The switching of the output alarm on is signaled by the highlight of the triangular alarm index, at the left side of the display for the suitable alarm digit
The highlight colour is always different from the colour of the displayed (measured) value. The protection level from the frontal side is IP 65. Meter overall dimensions: 96 ´ 48 ´ 64 mm (including terminals).
The N21 meter is a digital programmable panel mounted instrument designed to measure d.c. voltages or d.c. currents: unipolar or bipolar, temperature with use of thermocouples J (Fe-CuNi), K (NiCr-NiAl) and Pt100 resistance thermometers. The readout field is an OLED graphic display with a resolution of 32×128 points.
The eCon program is designed for the configuration of the N21 meter. The meter should be connected to a PC via a mini USB connector located on the rear of the meter.
Following parameters can be set:
• Measuring input
• Display precision of the result (decimal point)
• Relay output operating mode
• Thresholds triggering the relay output
• Time delays of the relay output triggering
• Individual characteristic for measuring signal
• Automatic or manual temperature compensation of cold junctions
• Averaging time of the measurement
• User-defined units of measured signal
• Bargraph configuration.
Meter output signals are isolated from the input signals and power supply.
Meters of the N24 and N25 series are digital instruments destined for the measurement of d.c. voltage or d.c. current: uni or bipolar, temperature through J, K thermocouples, Pt100 resistance thermometers and for the measurement of a.c. voltage and a.c. current. A LED display (4 digits for N24 and 5 digits for N25 meter series) constitutes the readout field. The LPCon program is destined for the configuration of N24 and N25 meter series. One must connect the meter with the PC computer through the PD14 programmer.
Following parameters can be reprogrammed:
– thresholds of displayed overflows,
– precision of the displayed result (decimal point),
– measurement averaging time ,
– counting of indications (individual characteristic),
– automatic or manual compensation: cold junction temperature for measurements with thermocouples, or wire resistance for Pt100 measurements (only in N24T and N24S meters).
All meters are galvanically separated between the supply, measuring inputs and the programmer input
Protection grade from the frontal side: IP65.
Meter overall dimensions: 96 x 48 x 64 mm (with terminals).
Meters of the N24 and N25 series are digital instruments destined for the measurement of d.c. voltage or d.c. current: uni or bipolar, temperature through J, K thermocouples, Pt100 resistance thermometers and for the
measurement of a.c. voltage and a.c. current. A LED display (4 digits for N24 and 5 digits for N25 meter series) constitutes the readout field. The LPCon program is destined for the configuration of N24 and N25 meter series. One must connect the meter with the PC computer through the PD14 programmer.
Following parameters can be reprogrammed:
– thresholds of displayed overflows,
– precision of the displayed result (decimal point),
– measurement averaging time ,
– counting of indications (individual characteristic),
– automatic or manual compensation: cold junction temperature for measurements with thermocouples, or wire resistance for Pt100 measurements (only in N24T and N24S meters).
All meters are galvanically separated between the supply, measuring inputs and the programmer input
Protection grade from the frontal side: IP65.
Meter overall dimensions: 96 x 48 x 64 mm (with terminals).
N27D meters are designed for direct a.c. measurement of voltage, current, frequency and active power. The design allows for installation of the meter for modular switchgear in accordance with EN 62208 (meter has a width of 3 modules) on 35 mm rail. The current is measured through current transformer (CT). Measured values are displayed on 4 -digit readout field. Switching between measured values is realized by pressing a button.
The N27P is a programmable digital device used to measure the parameters of single-phase electrical networks. The meter measures and calculates the following values:
phase voltage
10 minutes’ mean voltage
current
active power
reactive power
apparent power
active power factor
ratio of reactive/active power
mean active power
phase shift
input of active energy
output of active energy
input of reactive energy
output of reactive energy
apparent energy
frequency
10 seconds’ mean frequency
time
maximum and minimum values of:
– phase-to-neutral voltage;
– current;
– active power;
– reactive power;
– apparent power;
– active power factor;
– tangent φ;
– frequency;
– average active power;
It is possible to enter transformer ratio of used external current or voltage transformers which will be accounted for in the measurement and calculation of all values. All values and configuration
parameters are accessible through the RS485 and USB interfaces.The meter output signals are galvanically isolated from the input and power supply signals.
The N30H meter is a programmable digital panel meter destined for the measurement of d.c. voltage or d.c. current. Additionally, the meter enables the indication of the current time. The readout field is a LED display, which allows the exposition of results in colours: red, green and orange. The measured input signal can be arbitrary converted by means of a 21-point individual characteristic.
Features of the N30H meter:
l display colour individually programmed in three intervals,
l programmable thresholds of displayed overflows,
l 2 NOC relay alarms operating in 6 modes,
l 2 switched relay alarms with a switching contact operating in 6 modes (option),
l signaling of the measuring range overflow,
l automatic setting of the decimal point,
l programming of alarm and analog outputs with the reaction on the chosen input quantity (main or auxiliary input),
l real-time clock with the function of the clock supply support in case of the meter supply decay,
l programmed averaging time – function of walking window with the averaging time up to 1 hour,
l monitoring of set parameter values,
l interlocking of introduced parameters by means of a password,
l recount of the measured quantity on the base of a 21-point individual characteristic,
l service of the interface with MODBUS protocol in the RTU mode (option),
l conversion of the measured value into a standard – programmable current or voltage signal (option),
l highlight of any measuring unit acc. to the order.
l signaling of alarm operation – switching the alarm on causes the highlight of the output number,
l galvanic separation between connectors: alarm, supply, input, analog output connections and RS-485 interface.
Protection degree from frontal side: IP65
Meter overall dimensions: 96 x 48 x 93 mm (with terminals).
The meter casing is made of plastics.
The programmable digital panel meter N30O is destined for measurements:
number of pulses, frequency, period, work-time, encoder position. Additionally, the meter enables the indication of the current time. The readout field is a LED display, which allows the exposition in colors: red, green and orange. The measured input signal can be arbitrary converted by means of mathematics functions and/or a 21-point individual characteristic.
Features of the N30O Meter:
l display colour individually programmed in three ranges,
l programmable thresholds of displayed overflows,
l 2 NOC relay alarms operating in 6 modes,
l 2 switched relay alarms with a switching contact operating in 6 modes (option),
l signaling of measuring range overflow,
l automatic setting of the decimal point,
l programming of alarms and analog outputs with the reaction on the selected input quantity (main or auxiliary input),
l additional counter input,
l control inputs of the main input work, additional or both simultaneously,
l signaling of additional input state,
l possible control of counter operation by means of the meter keyboard,
l automatic reset of counters at the set point value
l real-time clock with the function of the clock supply support in case of the meter supply decay,
l programmed averaging time – function of walking window with the averaging time up to 1 hour,
l monitoring of set parameter values,
l locking of introduced parameters by means of a password,
l mathematic functions for measured value calculation,
l recount of the measured quantity on the base of the 21-point individual characteristic,
l interface with MODBUS protocol in the RTU mode (option),
l firmware updating by RS485 interface (option)
l conversion of the measured value into a standard – programmable current or voltage signal (option),
l highlight of any measuring unit acc. to the order.
l signaling of alarm operation – switching the alarm on causes the highlight of the output number,
l galvanic separation of pulse inputs between them,
l galvanic separation between terminals: alarm, supply, input, analog output, auxiliary supply, RS-485 interface.
Protection grade from frontal side: IP65
Meter overall dimensions: 96 x 48 x 93 mm (with terminals).
The meter casing is made of plastic.
The N30U meter is a programmable digital panel meter destined for measurements of signals originating from standard sensors destined for temperature measurements and for the measurement of analog standard signals applied in automation. Additionally, the meter enables the indication of the current time. The readout field is a LED display, which allows the exposition of results in colors: red, green and orange. The measured input signal can be arbitrary converted by means of a 21-point individual characteristic.
Features of the N30U meter:
l display colour individually programmed in three intervals,
l programmable thresholds of displayed overflows,
l 2 NOC relay alarms operating in 6 modes,
l 2 switched relay alarms with a switching contact operating in 6 modes (option),
l signaling of measuring range overflow,
l automatic setting of the decimal point,
l programming of alarm and analog outputs with the reaction on the selected input quantity (main or auxiliary input),
l real-time clock with the function of the clock supply support in case of the meter supply decay,
l programmed averaging time – function of walking window with the averaging time up to 1 hour,
l monitoring of set parameter values,
l locking of introduced parameters by means of a password,
l recount of the measured quantity on the base of the 21-point individual characteristic,
l service of the interface with MODBUS protocol in the RTU mode (option),
l conversion of the measured value into a standard – programmable current or voltage signal (option),
l highlight of any measuring unit acc. to the order,
l signaling of alarm operation – switching the alarm on causes the highlight of the output number,
l galvanic separation between connections: alarm, supply, input, analog output, output of the auxiliary supply, RS-485 interface.
Protection grade from frontal side: IP65
Meter overall dimensions: 96 x 48 x 93 mm (with terminals).
The meter casing is made of plastic.
NA3 series meters with a multi-colored bargraph have an universal input destined to measure temperature, resistance, voltage from shunts, standard signals, d.c. voltage and d.c. current. NA3 meters can optionally have a continuous analogue output, relays, OC type (Open Collector) and digital RS-485 outputs. They can find application in various industrial fields, e.g. food industry, intermediate pumping stations, sewage treatment plants, chemical industry, weather stations, breweries.
NA3 meters are executed in three basic versions:
NA3-F with a 4-digit LED readout field (digit height: 7 mm) and a multicolour bargraph,
NA3-D with a 4-digit LED readout field (digit height: 14 mm),
NA3-B with a multicolour bargraph.
The type choice is made in the execution code.
They are programmed by means of the keyboard and through RS-485. Meters only with the bargraph can be programmed through RS-485.
NA3 meters realise following functions:
– measurement of the input quantity and displaying it on the display and/or the bargraph,
– evaluation of the input signal into indication on the base of the individual linear characteristic,
– programming of the colour and bargraph resolutions (no concerns NA3-D),
– signalling of alarm value setting exceeding,
– recording of the measured signal in programmed time segments,
– storage of maximal and minimal values,
– programming of the indication resolution,
– programming of the measurement averaging time,
– locking of the parameter introduction by means of a password,
– conversion of the measured quantity into a voltage or current output signal,
– service of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode.
NA5 series meters with multicoloured bargraphs have an universal input destined to measure temperature, resistance, voltage from shunts, standard signals, d.c. voltage and d.c. current. They can find application in various industrial fields, e.g. food industry, intermediate pumping stations, sewage treatment plants, chemical industry, weather stations, breweries. They are destined for the visualisation of the measured value and evaluation of change trends of checked technological processes. They can also find application in automation systems where programmed controllers are applied. NA5 meters can have in option: a continuous analogue output, a relay output, open collector (OC) type outputs and an RS-485 digital output. They are programmed by means of the keyboard and through RS-485.
NA5 meters realise following functions:
– measurement of the input quantity and displaying it on the display and the bargraphs,
– recounting of the input signal into indication on the base of the individual linear characteristic,
– arithmetical functions: raising to a power, extraction of roots,
– programming of colours and bargraph resolutions,
– signalling of alarm value setting exceedings,
– recording of the measured signal in programmed time segments,
– storage of maximal and minimal values,
– programming of the measurement averaging time,
– programming of the indication resolution,
– deadlock of the parameter introduction by means of a password,
– conversion of the measured quantity into a voltage or current output signal,
– service of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode.
NA6 series meters with multicoloured bargraphs have an universal input destined to measure temperature, resistance, voltage from shunts, standard signals, d.c. voltage and d.c. current. They can find application in various industrial fields, e.g. food industry, intermediate pumping stations, sewage treatment plants, chemical industry, weather stations, breweries. They are destined for the visualization of the measured value and evaluation of change trends of checked technological processes. They can also find application in automation systems where programmed controllers are applied.
NA6 meters can have in option: a continuous analogue output, a relay output, open collector (OC) type outputs and an RS-485 digital output. They are programmed by means of the keyboard and through RS-485.
NA6 meters realise following functions:
– measurement of the input quantity and displaying it on the display and the bargraphs,
– recounting of the input signal into indication on the base of the individual linear characteristic,
– arithmetical functions on channels: addition, subtraction, multiplication, division, raising to a power, extraction of roots,
– programming of colours and bargraph resolutions,
– signalling of alarm value setting exceedings,
– recording of the measured signal in programmed time segments,
– storage of maximal and minimal values,
– programming of the measurement averaging time,
– programming of the indication resolution,
– deadlock of the parameter introduction by means of a password,
– conversion of the measured quantity into a voltage or current output signal,
– service of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode.
NC12 clamp-on meter has been designed to measure AC/DC currents and voltages, as well as capacitance, circuit continuity, resistance, frequency, duty cycle and temperature.
The innovative product design increases comfort and safety of the user. The unique design of the rotary measuring component (clamps) allows for measurements in places with a difficult access.The jaws can be opened and closed by using a special lever placed under the meter, which allows the user to keep their arm at a safe distance from the measured parts of the system, thereby reducing the risk of an electric shock.