Showing 49–62 of 62 results

P30H-Transducer of D.C. circuit parameters with data record and Ethernet

P30H is a transducer which was designed to photovoltaic , battery, telecommunication and railway installations. P30H measures and records current, voltage, power, energy and other d.c. circuit parameters.

The output signal is galvanically isolated from the input signal and the power supply.
P30H has programmable measurement and additional functions.
Programming parameters can be realized with the use of buttons, via RS-485 interface and free e-con software or Ethernet or any web browsers.

Transducer is available in 3 versions:

  • basic,
  • with SD/SDHC card,
  • with Ethernet and internal file system memory.

P30P-Transducer of 1-Phase Power Network Parameters with Data Record & Ethernet

P30P is a titransducer which was designed to measure 1-phase power network parameters. It can measure and record up to 16 parameters
 

The output signal is galvanically isolated from the input signal and the power supply.
P30P has programmable measurement and additional functions.

Transducer is available in 3 versions:

  • basic,
  • with SD/SDHC card,
  • with Ethernet and internal file system memory.

P30U-Universal transducer of temperature and standard signals with data records and Ethernet

P30U transducer is designed to convert temperature, resistance, standard voltage and current signals into a standard DC voltage or DC current signal.
The output signal is galvanically isolated from the input signal and the power supply.
P30U has programmable measurement and additional functions.
Programming parameters can be realized with the use of buttons, via RS-485 interface and free e-con software or Ethernet or any web browsers via Ethernet interface.

Panel Pointer Frequency Meter

Pointer frequency meters are moving-coil meters with built-in measuring transducers intended for measuring
voltage frequency in AC electrical networks. These meters can be mounted on panels of any kind of materials.

Panel Power Factor Meter With Built-in Transducer

Panel power factor meters are destined for measurements of the phase angle between the voltage and current in single phase or three-phase AC power networks. These meters are calibrated to correspond to the cosine of the angle, i.e. the power factor. These meters can be mounted on panels of any kind of materials.

Panel Power Meter

The power meter is a mowing-coil meter with a built-in measuring transducer. It is destined to measure active or reactive power in a.c. power networks. The measured power is indicated by a magnetoelectric (moving-coil) measuring system.

These meters are delivered in following versions:
– for measuring the active power in single-phase systems,
– for measuring the active or reactive power in three-phase
three-wire or four-wire symmetrically or asymmetrically loaded systems,
– with the zero graduation on the left side of the scale for measuring the unidirectional power flow,
– with the zero graduation in the middle of the scale for measuring the bidirectional power flow.

Power Network Analyser

The N100 meter is a programmable digital instrument designed for the measurement of 3-phase, 3 and 4-wire power network parameters in balanced or unbalanced systems. The measured values are displayed on a two-color LED display. The meter enables control and optimization of the power electronic devices, systems and industrial installations. The meter provides measurement of: RMS of voltage and current, active, reactive and apparent power, active, reactive and apparent energy, power factors, frequency, the harmonics of current and voltage /up to 51st/, THD of voltage and current, averaged active and apparent power P Demand, S Demand, averaged current I Demand /15, 30 or 60 minutes/. Voltages and currents are multiplied by given voltage and current ratios of the measuring transformers. Power and energy indications take into account all programmed ratio values. The value of each measured value can be transmitted to the master system via the RS-485 or Ethernet interface. Three relay outputs signal the overflow of the chosen value, and the pulse output can be used for the consumption check of 3-phase active energy. The programmable analog outputs map the assigned parameter. The pulse input can be used to check the counters with the pulse outputs.
There is a galvanic separation between following units of the meter:
–– supply
–– voltage inputs
–– current inputs
–– RS485 interface
–– Ethernet interface
–– pulse input
–– pulse output OC
–– alarm outputs
–– analog outputs

POWER NETWORK METER VPS10

VPS10 measures the basic network parameters in 3-phase networks (3- or 4-wire) or 1-phase networks. The meter can replace many analogue instruments.

Power Network Meter VPS11

VPS11 measures the basic network parameters in 3-phase networks (3- or 4-wire) or 1-phase networks. The meter can replace many analogue instruments.

Power Network Meter VPS50

VPS50 measures the most important parameters in 3-phase (3- or 4-wire) or 1-phase networks. VPS50 measures over 46 different power network parameters.

Rail Mounted Power Network Meter

The N43 meter,assembled on a rail, is a programmable digital instrument designed for the measurement of 3-phase, 3 or 4-wire power network parameters in balanced or unbalanced systems. The measured values are displayed on a dedicated LCD display. The meter enables control and optimization of the power electronic devices, systems and industrial installations. The meter can be used for measuring: RMS of voltage and current, active, reactive and apparent power, active and reactive energy, power factors, frequency,THD and averaged values P Demand – “power guard”, S Demand, I Demand /15, 30 or 60 minutes/. Voltages and currents are multiplied by given voltage and current ratios of the measuring transformers /for indirect
connections/. Power and energy indications take into account all programmed ratio values. The value of each measured value can be transmitted to the master system via the RS-485 interface. Three relay outputs signal the overfl ow of the chosen quantity, and the pulse output can be used for the consumption check of 3-phase active energy.

There is a galvanic separation between following units of the meter:
– supply,
– voltage and current inputs,
– RS-485,
– USB,
– pulse output OC,
– alarm outputs.

Screen Recorder KD8

The KD8 recorder is applied as a data acquisition station in measuring systems. It finds application to measure, visualize and supervise technical process parameters in various industrial branches, e.g. in pharmacy, food, chemical.
 

Three Phase Power Network Meter

The N14 meter is a programmable digital panel instrument destined for the measurement of 3-phase, 3 or 4-wire power network parameters, in balanced or unbalanced systems with the simultaneous display of measured quantities and digital transmission of their values. This network parameter meter enables the control and optimization of power electronic devices, systems and industrial installations. The N14 meter ensures the measurement of: RMS voltage and current, active, reactive and apparent power, active and reactive energy, power factors, frequency, mean active power (e.g. 15-min mean power). Voltages and currents are multiplied by given current and voltage ratios of measuring transformers. Indications of power and energy take into consideration programmed ratio values. The value of each measured quantity can be transmitted to the master system through the RS-485 interface. The relay output signals the exceeding of the chosen quantity and the impulse output can be used for the consumption control of the 3-phase active energy. The meter has a detection and signaling of incorrect phase sequence. The meter is fixed to the panel by means of screw holders.