Showing 17–32 of 102 results

Data Logger with WWW server – SM61

SM61 is a new and practical solution, which provides you continuously visualization of process parameters by any web browser from the most distant places of the world. For communication with SM61 you can use PC, tablet or mobile phone with a web browser.

DC Transducer VTR05

VTR05 ensures galvanic isolation between input, output and the supply circuit. The transducer meets all the requirements concerning EMC according to PN-EN 61010 standard.

DL11, DL12, DL13 Large Size Digital Display

Large-size digital displays of DL type are destined to display measured values o set values through the communication interface. Taking in consideration the application of 7-segment LED displays they are destined to be installed inside buildings.

The 100 mm digit height ensures a good readout from the distance of 40 m. They find application in office accommodations , production workshops, in production management rooms as information about production parameters, state of machines or devices. The displayed value is transmitted from external devices working in MODBUS standard. The display is working as the network „master”. The basic display version includes three digits and the unit, in two rows or three rows.

DL21 Numerical Diplay Panel

DL21 numerical display panels are destined to display numerical values read out from a connected device or assigned value through the programming interface in the selected colour by the user. Considering the luminosity of display segments and the housing design they are destined for indoor applications. These display panels find application to display numerical quantities in office rooms, production halls in management points as information about production parameters, machine state, device working state, etc. The displayed value on the display can originate from external devices operating in MODBUS standard, and at the same time it is possible to configure the display to work as “Master” or “Slave”. Moreover, the display enables to connect 10 slave devices to it, and this make possible to fulfill the task of a local point of data acquisition. All data read out from slave devices can be read out through the RS-485 interface. The value can be displayed in the chosen colour (green, red or orange) by the user or the display colour can be changed depending on the indicated value. Moreover, the minimal and maximal indicated value is defined by the user. DL21 display panels are equipped with two RS-485 communication interfaces operating in the MODBUS RTU standard. One of the interfaces is destined to connect slave devices, whereas the second interface is destined to configure the display or to introduce the displayed value ( the display fulfills the part slave in the MODBUS network). The basic display execution includes three digits and the place destined to locate the unit. It is possible to make a display composed of DL21 digits in the configuration defined by the user.

DN1, DN2, DN3 Large Size Numeric Displays

Digital displays of DN type can be applied for the visualisation of essential parameters in automation and measurement processes when supervising the quality or working safety. Information put in a visible place helps in the efficient work in industrial communication, logistics, automation and control technology, and material handling. These displays are destined to be installed in: industrial plants, sports objects, trade buildings and communication areas. The character height ensures a good visibility and reading from a long distance, up to 120 m.

Digit heights: DN1 – 100 mm; DN2 – 200 mm; DN3 – 300 mm. Digital displays are offered in four colours: red, green, yellow and blue.

Basic installations are applied for measurements and indications of: temperature, humidity, time, pressure, flow, rotations, pulses, and also the gas content and material quantity. These DN displays together with an external measuring element or transducer can display any physical quantity and co-operate with external sevices equipped with an RS485 digital output with the MODBUS RTU/ASCII protocol. The configuration of transmission parameters and measuring ranges is made agree with the customer. Each customer obtains a service manual together with the display unit. The standard version includes the digital diode display field and the unit field. The number of characters and the display colour are expressed by the ordering code or defined by the customer. The display field brightness is established automatically in accordance with external conditions. The unit can be selected from the list inserted

DNL2, DNL3 Numerical Digital Display Panel

LED DNL digital display panels are designed for display of digital values indoor: offices, manufacturing plants or production supervision points, providing information such as production parameters, machine condition, device operational status etc.

DNL display panels can be configured with LPCon software application available for free on the website www.lumel.com.pl. DNL display panels are equipped with two RS485 communication interfaces using MODBUS RTU standard. First interface (programming interface) is used for the configuration of the display panel settings or for the input of displayed value (the display panel is a Slave device in MODBUS RTU network) e.g. from the SCADA application or PLC drivers Second interface (object interface) is used for plugging slave devices (the display panel is a Master device in MODBUS RTU network) the display panel gets displayed data from. Display panel configuration allows reading up to 100 registers from slave devices (up to 10 registers per each of 10 devices), so the display panel can act as the local data collection point. All data received from slave devices can be accessed as internal registers of the display panel for the SCADA application or PLC drivers via RS485 MODBUS RTU Slave interface. It is possible to define minimum and maximum displayed value for the display panels. Additionally, the display panel may be equipped with auxiliary measurement input for the measuring of standard analog signal 4..20 mA used in automatics and with output powering external measurement transducers. Basic configuration of the display panel includes one or two fields for readings (4 digits each) and space for the unit placement.

Dual Loop Controller/Programmer

The RE19 dual loop controller/programmer is destined to control temperature or other physical quantities, e.g. pressure, humidity, level, converted into an electric signal. It can independently control two objects or two physical quantities in one object, e.g. in two-zone furnaces.

This controller is available in three versions:

  • RE19 S for standard (fixed set point) control,
  • RE19 P for standard control or programmed control
    – 15 programs with 15 segments in each program,
  • RE19 V for standard control by motorised valve control
    – at choice, 2 algorithms of stepper control, with or without feedback.

The controller can be equipped with the RS-485 interface with MODBUS protocol.

HMI Operator Panels

The Operator Panel is one of the tools designed for process operators. The panel is a graphical interface between its user and the process. It provides the user with the following functions: control, monitoring, visualization and process management. The operator using the panel has the ability to enter data and control devices via the touch screen. The device is designed to work with PLCs, controllers, transmitters and other devices. The Operator Panel ensures simple control of a process, e.g. by selecting a predefined set of parameter settings, entering values from the keyboard , generating alarms and warnings, and creating reports that include important parameters changes during the process, e.g. for the quality management department of a plant. Advanced features of the device, such as animations, trends, data acquisition, logging, and securing data facilitate operator’s work and provide information for optimizing the process. Advanced visualization and a wide range of functions also help to minimize operational errors, improving the process quality.

A control algorithm for the panel is created on a PC for specific solutions of the control system and then it is sent to the panel via Ethernet connection or downloaded from USB drive. The algorithm is created with “Panel Studio” – an effective programming tool, which does not require knowledge of any programming language and operates on any PC with Windows XP / VISTA / 7/ 8. This software is equipped with communication drivers for many devices and an extensive library of functional modules that facilitate configuring functions of the panel, fault diagnostics and designing dialogues with the user. An application algorithm is created by inserting prepared library objects into design sheets and setting parameters of these objects in accordance with requirements.

•Technological process visualization

• Remote control of many automation components from one place
• Integration of automation devices working with different communication protocols
• Data logging for technological processes

• Rich library of graphic elements
• Large communication possibilities (service of over 200 communication drivers, at least 2 serial ports, USB Host, optionally Ethernet)
• Storage of data, alarms and events (battery operated memory)
• Alarms, recipes, reports, macros (simple control)

• operation in though conditions (IP65 from front side)
• High security level
• Free Panel Studio tool software

HT20 Temperature & Humidity Monitor

HT20 monitor has been designed to measure, monitor and record temperature and humidity.
It is a perfect solution for any facilities where monitoring and recording such values are very important for the accuracy of the whole process (for example, in server rooms, drug and food warehouses, laboratories, museums or glasshouses). The data captured by HT20 is stored in the internal memory and then sent digitally to the user (by the Ethernet). In case of an emergency situation, the device immediately sends appropriate warnings via emails or via a website. An additional advantage of H20 is the possibility that it can be powered over the Ethernet. This feature is available in versions that are equipped with the Power over Ethernet system (PoE).

KD7 Screen Recorder

The KD7 screen recorder is applied as a data acquisition station in measuring and control systems.
It finds application to measure, visualize and supervise technical process parameters in various industrial branches, e.g. pharmacy, food, chemical and papermaking industries. It can be also used as an autonomous measuring and recording device. The KD7 screen recorder is adapted to measure voltage, current, temperature, resistance changes and other quantities converted into a signal or electrical parameter. The source of measuring data can be also communication interfaces (ETHERNET, RS-485).
All processes suitable for a measuring system can be realized in this recorder: measurement of input
signals and their conversion, visualization and archiving of data, signaling and communication with
the environment. Converted measuring data are stored in the internal memory and on the CompactFlash card.

Moving-Iron Voltmeter with a change-over switch

The moving-iron panel voltmeter with a change-over switch is adapted for measuring line-to-line and phase-to-phase RMS voltages in 3-phase 4-wire power networks. A six-positional switch installed on the meter frontal side enables the choice of the measured voltage in six different points of the network system.

MR03 High Power Radio Transmission Module

The MR03 high power radio transmission module is destined to change the information transmission medium from the cable transmission with RS-232 and RS-485 interface into a wireless transmission in the radio channel in the non-licensed band 869.40 – 869.65 Mhz with the output power 500 mW. The module MR03 finds application in telemetric system applications, in which there is no technical possibilities to conduct a cable to connect devices in a wired network. In such cases , the module is used as a bridge which partially will carry out the transmission through the radio way. The maximal operation range of the MR03 module is 1.5 km in average, and depends on the terrain configuration and the applied antenna.
Accessible MR03 working modes:
l transparent,
l multipoint,
l point-to-point,
allow the creation of an extensive network of radio modules to fit the needs application requirements. Necessary parameter changes to the correct module work are carried out by means of the added configuration program ECon. 

N20 Digital Panel Meter

The N20 meter is a digital programmable panel instrument destined for measurements of d.c. voltages or d.c. currents: unipolar or bipolar, temperature through thermocouples (J, K) and Pt100 resistance
thermometers. The readout field is a LED display which enables the exposition of results in red, green or orange colours. The LPCon program is destined for the configuration of the N20 meter. The N20 meter must be connected to the PC computer through a PD14 programmer.
Following parameters can be reprogrammed:
– display colour, individually in three intervals,
– thresholds of displayed overflows
– display precision of the result (decimal point),
– highlight of the unit,
– automatic or manual compensation: temperature of ends in measurements with thermocouples, or wire resistance in Pt100 measurements,
– averaging time of the measurement,
– recalculation of indications (individual characteristic),
– two alarms of OC type operating in six working modes.
The alarm output switching on is signaled by the highlight of the triangular alarm index situated at the left display side, for the suitable alarm digit. The highlight colour is always different from the colour of the displayed (measured) value. The meter has a galvanic separation between the supply, measuring inputs and the programmer input. The protection level from the frontal side is IP65. Meter overall dimensions: 96 ´ 48 ´ 64 mm (including terminals).