Digital multimeter NP10 type is widely used in the electrical, electronics industry, service works, and as a training – learning tool.
The multimeter allows for measurement of AC/DC voltage, resistance, capacitance and frequency, and also duty cycle, peak values and temperature. Aesthetically constructed dual backlit LED display ensures easy reading of the measured parameters.
The multimeter is available in four versions: NP10-2, NP10-3, NP10-5 i NP10-6 TRMS.
Detailed information is available in the data sheet.
TRUE RMS digital multimeter NP15 is a complete tool for testing and measuring equipped with over 30 different functions. It is characterized by a high level of safety, high measurement resolution, wide measuring range, reliability and durability.
When designing NP15 special attention was paid to the safety of use of the device and its functionality, through the use of, among others, the function of signaling the presence of dangerous voltage at the terminals of the meter, the buzzer informing about exceeding the preset range, the use of one common fuse in a separate pocket for all current measurement ranges from 600μA to 10 A AC/DC, or the intuitive MENU of the instrument.
The multimeter is available in four versions: NP15-2, NP15-3, NP15-5 i NP15-6.
Detailed information is available in the data sheet.
NP40 is the professional device to analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system.
The PC software can simply upload the data to PC for full analysis.
Insulation meter NT10 features a large backlit LED display and its compact and robust design makes NT10 meter a reliable and easy-to-use instrument.
This product is designed to measure AC/DC voltage and current, frequency, resistance, circuit continuity, diode, capacitance, to perform current measurements using clamps and insulation resistance measurements.
The OPT-700 is a Fiber Optic Modem designed to provide a versatile connection between asynchronous serial communication interfaces such as RS-232c and RS-485 using Fiber Optic cable. It will allow any equipment that uses half-duplex asynchronous serial communication at typical distances up to 4.0 km with the great benefit of EMI immunity.
It can be configured point-to-point or in a multi-drop configuration using the Repeat feature.
The OPT-700 supports a broad range of configurable baudrates for the asynchronous serial communication. RS-232C can work between 2400 to 115.2Kbps while RS-485 works from 2400 till 920Kbps.
Once Fiber Optic is immune to EMI/RFI and ground loops, the Modem can replace converters and isolators when connecting remote devices.
The P17G passive separator in a housing of 6.2 mm width, serves for the electric isolation and filtration of the 0(4)…20 mA standard signal value without an additional supply voltage.
The P20 programmable transducer is destined to convert the temperature, resistance, voltage from shunt and standard signals into a standard constant-current or constant-voltage signal.
The transducer output signal is galvanically insulated from the input signal and the supply.
Transducers of P20H types are applied for the continuous conversion of d.c. voltage and d.c. current into a standard d.c. current, d.c. voltage signal or RS-485 digital signal.
Measuring transducer P20Z type is destined to a continuous conversion of the rms current value or alternating voltage without the constant component into a standard d.c. current or d.c. voltage signal.
The transducer output signal is galvanically insulated from the input signal and the supply.
P30H is a transducer which was designed to photovoltaic , battery, telecommunication and railway installations. P30H measures and records current, voltage, power, energy and other d.c. circuit parameters.
The output signal is galvanically isolated from the input signal and the power supply.
P30H has programmable measurement and additional functions.
Programming parameters can be realized with the use of buttons, via RS-485 interface and free e-con software or Ethernet or any web browsers.
P30U transducer is designed to convert temperature, resistance, standard voltage and current signals into a standard DC voltage or DC current signal.
The output signal is galvanically isolated from the input signal and the power supply.
P30U has programmable measurement and additional functions.
Programming parameters can be realized with the use of buttons, via RS-485 interface and free e-con software or Ethernet or any web browsers via Ethernet interface.
Pointer frequency meters are moving-coil meters with built-in measuring transducers intended for measuring
voltage frequency in AC electrical networks. These meters can be mounted on panels of any kind of materials.
Panel power factor meters are destined for measurements of the phase angle between the voltage and current in single phase or three-phase AC power networks. These meters are calibrated to correspond to the cosine of the angle, i.e. the power factor. These meters can be mounted on panels of any kind of materials.